Text Box: Compatible With:

Octopus 4000
Octopus 3000

  

In-line compression fittings

Text Box: Calibration solutions

Learn about care and storage of Aquadyne probes.

 

 

 

 

 

 

Text Box: Conductivity Probe with 10-ft. cable (custom cable lengths available, must be requested at time of order, 5-ft increments, allow 3 weeks for delivery) and mini-DIN connector. Sturdy ¾-in. PVC body protects graphite electrodes from damage. Manufactured in the USA. 90 day warranty.
Specifications:
·        Low Range: 0-1,999 μS 
·        High Range: 0-199 mS 
·        Digital Single Reference Point Calibration
·        0-5% User Adjustable Temperature Compensation
·        Accuracy: +/- 3%
·        Resolution: 1 μS (Low Range)/0.01 mS (High Range)
·        Pressure Range: 0-100 psig
·        18-24 Month Life Expectancy
The Conductivity Probe must be installed using either a ¾-in. In-Line Probe Holder (44-000638), Conductivity Cell (44-010711) or a "drip cup" (see Users Manual for complete details). These installations provide a constant volume of measurement around the electrode allowing for maximum accuracy and repeatability. The Conductivity Probe must also be installed a minimum of 18-in. away from the temperature probe to ensure proper operation.
 
                       

 

                       

 

                   

           

                       

 

 

 

 

Text Box: Conductivity Probe with 10-ft. cable (custom cable lengths available, must be requested at time of order, 5-ft increments, allow 3 weeks for delivery)and Mini-DIN connector. Sturdy ¾-in. PVC body protects graphite electrodes from damage. Manufactured in the USA. 90 day warranty.
Specifications:
·        Low Range: 0-1,999 mS 
·        High Range: 0-199 mS 
·        Digital Dual Reference Point Calibration
·        0-5% User Adjustable Temperature Compensation
·        Accuracy: 3%
·        Resolution: 1 mS (Low Range)/0.01 mS (High Range)
·        Pressure Rating: 0-100 psig
·        24 Month Life Expectancy
The Conductivity Probe must be installed using either a ¾-in. In-Line Probe Holder (44-000638), Conductivity Cell (44-010711) or a "drip cup" (see Users Manual for complete details). These installations provide a constant volume of measurement around the electrode allowing for maximum accuracy and repeatability. The Conductivity Probe must also be installed a minimum of 18-in. away from the temperature probe to ensure proper operation.

 

 

 

 

 

 

 

 

                       

Text Box: Extends the cable length of the standard and laboratory grade conductivity probe an additional 25-ft., for a total length of 35-ft. Ideal for applications that require cable lengths greater then the standard 10-ft. length. 1 year warranty.
For applications in condensing environments, it is strongly recommended that a Water Resistant Junction Box be used to prevent corrosion of the cable connectors.